Please use this identifier to cite or link to this item: https://zone.biblio.laurentian.ca/handle/10219/2313
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDeng, Deng Ngang-
dc.date.accessioned2015-01-27T19:17:12Z-
dc.date.available2015-01-27T19:17:12Z-
dc.date.issued2015-01-27-
dc.identifier.urihttps://zone.biblio.laurentian.ca/dspace/handle/10219/2313-
dc.description.abstractA study to compare six magnetic susceptibility (MS) instruments (the KT-10 supplied by Terraplus Inc., RT-1 produced by Fugro, SM30 produced by ZH Instruments, MS2K & MS2C produced by Bartington Instruments and MPP-EMS2+ probe produced by GDD Instruments (denoted as GDD)) was conducted to characterize the equipment on the basis of their accuracies, resolution, reproducibility, ease of use and response to drift. MS data were collected on BQ core from 3 holes, NQ core samples, 2 rock samples and 2 calibration samples at the Vale office in Thompson, Manitoba. The results show that the GDD and MS2K are most affected by temporal drift whereas the KT-10 and MS2C gave more repeatable results. The MS2C, MS2K and GDD generally gave higher susceptibility readings than the rest of the meters. It was also noted that measurements on the flat face of half-core samples were always higher compared to measurements on their respective whole core samples. There is a correlation between instruments, frequencies and sensitivities, but no relationship between frequencies of operation and temporal drift. Keywordsen_CA
dc.language.isoenen_CA
dc.publisherLaurentian University of Sudburyen_CA
dc.subjectMagnetic susceptibility instruments,en_CA
dc.subjectmeasurementsen_CA
dc.subjecttemporal driften_CA
dc.subjectinstrument accuracyen_CA
dc.subjectdata qualityen_CA
dc.subjectquality control protocolsen_CA
dc.subjectcalibration standardsen_CA
dc.subjectlower limits of accuracyen_CA
dc.subjectfrequency dependenceen_CA
dc.subjectsensor size and inductive coilen_CA
dc.subjectcorrelationsen_CA
dc.subjectsensing areaen_CA
dc.titleA comparative study of hand-held magnetic susceptibility instruments.en_CA
dc.typeThesisen_CA
dc.description.degreeMaster's Thesesen_CA
dc.publisher.grantorLaurentian University of Sudburyen_CA
Appears in Collections:Earth Sciences / Sciences de la Terre - Master's Theses
Master's Theses

Files in This Item:
File Description SizeFormat 
MSC Thesis Submission_Deng_2.pdf6.88 MBAdobe PDFThumbnail
View/Open


Items in LU|ZONE|UL are protected by copyright, with all rights reserved, unless otherwise indicated.